4
© Copyright Advanced Keys Inc. 2011. All Rights Reserved.
---MAIN HARNESS WIRING DESCRIPTIONS
Main Harness 8-Pin 14-16 Gauge
-
-) triggered Starter input. This output
is rated for 500mA. -) side directly.
IMPORTANT:Ensure that the ignition current is not rated more than 30A. Connect to external relay with
higher current rating if required.
Connect to a constant +12V supply wire at the ignition switch. Ensure that the OEM input power wire is
fused for more than 30A.
Note:
box or connect directly to the B+ terminal on the battery.
ON 2 / 2nd Ignition Output
This output will be +12V in ON and RUN state and OFF during Start (crank) State.
ON 1 / Primary Ignition Output
Connected to bare, unpainted metal on chassis. It is recommended to use a factory ground bolt rather
than a self-tapping screw. Screws tend to get loose or rusted over time and lead to erratic electrical
problems.
Connect to a constant +12V supply wire at the ignition switch. Ensure that the OEM input power wire is
fused for more than 30A.
Note:
box or connect directly to the B+ terminal on the battery.
OFF during START (crank) state.
Ignition Outputs State Table:
Following table shows state of the ignition outputs when system is in ACC, ON, START and RUN mode:
OPTIONAL
CONNECTIONS - HARNESS